A regular contribution from Bob Schmid, WA9FBO
Keeping your cool
Let’s look at the basics of heat sinking—and why it matters. As temperature rises, the life of electronic components falls. The good news is that we don’t have to guess whether something will run hot. By treating the thermal path like a simple circuit, we can estimate temperature and see what’s really going on.
One important point: heat is generated at the junction inside the device. That means the junction is always hotter than the case—and often by more than you might expect. Even if the outside feels only warm, the inside can be much hotter.
Thermal resistance
We need a way to describe how easily heat moves from one place to another, and that’s where thermal resistance comes in. Just as electrical resistance limits the flow of current, thermal resistance limits the flow of heat. When heat flows through a material, a temperature difference develops across it—the greater the resistance, the larger the temperature rise for a given amount of heat.
In a real device, heat doesn’t travel through just one layer. It moves from the junction, through the case, into the heat sink, and finally into the surrounding air. Each step has its own thermal resistance, and each one adds a bit more temperature rise along the way.
Thermal resistances are written using the Greek letter theta (θ), followed by two letters that describe the path the heat takes. For example, θJC means junction-to-case—the first step in the thermal path. Next is θCS, case-to-heat sink, followed by θSA, heat sink-to-ambient air. Following this convention, θJA refers to the entire path—from the junction all the way out to the surrounding air—and is simply the sum of the individual steps: θJA = θJC + θCS + θSA. The units are degrees Celsius per watt (°C/W).
(Thermal grease, pads, or tape is used to fill gaps in the heat sink surface and improves heat transfer. These materials don’t eliminate the resistance, but they reduce it and are included in the case-to-heat sink term, θCS.)
We find the temperature rise (°C) by multiplying the thermal resistance (°C/W) by the power (W). For example, if a device dissipates 5 W and heat sink A is rated at 10 °C/W, the temperature rise will be 50 °C. If heat sink B is rated at 2 °C/W, the rise is only 10 °C. Heat sink B is better—its lower °C/W rating means less temperature rise.
A familiar way to think about heat
Let’s compare a thermal path to something we already know (Fig. 1). On the left is a simple series circuit with a voltage source pushing current through a few resistors. On the right is the same idea, but applied to a thermal path.

In the electrical picture, we often imagine voltage “dropping” as we move from the supply down to ground. But that’s just a matter of viewpoint. We can just as easily start at ground and work upward, adding the voltage rise across each resistor until we reach the supply.
The thermal picture works the same way. Heat flows from the hot junction down to ambient, but if we start at ambient and work upward, each thermal resistance, from the heat sink, to the case, and finally to the junction adds a temperature rise. By the time we reach the junction, all of those rises add up to the highest temperature in the system.
(One difference from an electrical circuit is that there’s no thermal “return path.” Heat doesn’t flow in a loop—it simply moves from a hotter point to a cooler one, eventually reaching the surrounding air. In this analogy, ambient temperature acts like a reference point, similar to ground in a circuit.)
Estimating the junction temperature
Earlier we found the temperature rise by multiplying the total thermal resistance, θJA, by the power dissipation (P). If we add the ambient temperature (Ta), we get the junction temperature: Tj = Ta + P • θJA. Keep in mind that junction temperature limits matter. Some devices are rated for 150 °C, but many are limited to 125 °C—or even 100 °C. A result that looks acceptable at first glance can still push the device past its safe limit.
Choosing a heat sink
Assume we need a heat sink for a voltage regulator that has a maximum junction temperature of 125°C. The ambient temperature is 25°C (room temperature) and the power being dissipated is 5 watts. We can work backwards to find the total allowable thermal resistance: θJA = (Tj − Ta) / P. The maximum allowable temperature rise is 125°C − 25°C = 100°C. Dividing by the power: 100°C / 5 W = 20°C/W. So the total thermal resistance—from junction to air—must be 20°C/W or less.
Now look at what’s already fixed. The regulator’s datasheet specifies the junction-to-case thermal resistance, θJC, as 3°C/W. The thermal grease (or pad) adds another 2°C/W for θCS. That leaves: 20 − 3 − 2 = 15°C/W. So the heat sink needs to be rated 15°C/W or lower.
What the heat sink is really doing
It’s easy to think of a heat sink as something that “absorbs heat”, but what it really does is lower the thermal resistance between the device and the air (θSA). A bigger heat sink has a lower θSA. Better airflow lowers θSA too, and so does adding a fan. We don’t store heat; we give it an easier path out.
This article originally appeared in the November 2026 issue of the Tri-Bander.